01 · The Trust

Trusted in the Environments Where Power Cannot Fail

Hospitals

Critical Care · Surgical Suites

Data Centers

Colocation · Hyperscale

Government

Federal · DoD · Municipal

High-Rise

Commercial · Residential

02 · The Range

Every Critical Load. One Manufacturer.

All Products →
03 · The Match

Size Your System in 30 Seconds.

Pick the system type, enter your load, see the recommended model. Final specs always confirmed by our engineering team.

Runtime: 90 min per NFPA 101 §7.9 (120 min available). Pure sine wave output.

Your Recommendation

Enter your load to see the match.

We'll recommend the model and point you to the datasheet. Takes about 20 seconds.

Estimates are for planning. Final sizing is confirmed by our engineering team based on harmonic profile, crest factor, and load curve.
04 · The Proof

One Manufacturer. The Full Range.

Numbers that matter when the grid drops.

35W

– 400kW

Output Range

<4

ms transfer

UL 924 Response

10–500

kVA UPS

UL 1778 Certified

48+

years

Mission-Critical Builds

05 · Why It Matters

The Code Doesn't Ask Why.

Every number below comes from a standard, federal lab, or peer-reviewed source. When the grid drops or a panel fails, these are the thresholds that matter — and the citations AHJs read.

Power Quality

$44B

Annual cost of sustained US power interruptions

Lawrence Berkeley National Laboratory (2018) puts the economic cost of sustained outages at roughly $44 billion per year using peer-reviewed methodology.

LBNL · LaCommare, Eto et al. (2018)
Data Centers

54%

of data center outages cost over $100,000

Uptime Institute's 2024 analysis: half of significant outages now cross the six-figure threshold; one in five exceed $1M.

Uptime Institute · Annual Outage Analysis 2024
Emergency Lighting

90 min

Egress illumination required after grid loss

NFPA 101 §7.9 mandates 1½ hours of emergency illumination along every egress path. Full brightness on minute 89 is the test.

NFPA 101 · §7.9
UL 924 Response

10 s

Maximum activation time for emergency equipment

UL 924 requires emergency lighting and power equipment to reach full output within 10 seconds of normal-power loss. NFPA 110 Type 10 matches.

UL 924 · Emergency Lighting & Power Equipment
Fire Alarm

24 hr + 5 min

Standby + full-alarm duration required

NFPA 72 §10.6.7.2: secondary power carries 24 hours of standby plus 5 minutes of full alarm — 15 minutes with voice/MNS evacuation.

NFPA 72 · §10.6.7
Elevator

2 hr

Continuous evacuation power for safe egress

ASME A17.1 / IBC require a standby power source capable of operating the elevator and its accessories for safe evacuation during utility failure.

ASME A17.1 · Elevator Safety Code
Healthcare

Type 1

Essential Electrical System for Category 1 care

NFPA 99 requires a Type 1 EES restoring power within 10 seconds for any space where power loss could cause patient death. UL 60601-1 leakage limits stack on top.

NFPA 99 · Essential Electrical Systems
Medical Leakage

100 µA

Max chassis leakage for medical equipment

UL 60601-1 caps chassis leakage at 100 µA normal condition and 10 µA at the patient under single-fault condition — thresholds no standard UPS meets.

UL 60601-1 · Medical Electrical Equipment
Power Quality · ANSI

±5%

Utility service voltage tolerance (US)

ANSI C84.1 specifies ±5% utility service voltage tolerance. Sensitive equipment fails well inside that window — voltage regulation closes the gap.

ANSI C84.1 · Electric Power Systems & Equipment — Voltage Ratings
Harmonics

5% THD

Voltage distortion limit at the PCC

IEEE 519 limits voltage THD at the point of common coupling to 5%. Isolation transformers and harmonic-mitigating PDUs keep non-linear loads inside the window.

IEEE 519 · Harmonic Control in Electric Power Systems
Aerospace

400 Hz

Aircraft & defense electrical systems

MIL-STD-704 standardizes 400 Hz, 115 VAC three-phase power for US military aircraft. Ground-support gear requires frequency conversion from 60 Hz utility.

MIL-STD-704 · Aircraft Electric Power Characteristics
Sensitive Loads

IEEE 1100

Grounding for sensitive electronic equipment

IEEE 1100 (Emerald Book) recommends isolation with electrostatic shielding for sensitive electronic loads — the spec behind medical imaging and broadcast clean-power requirements.

IEEE 1100 · Emerald Book

Standards excerpts referenced for education only. Design-of-record documents govern AHJ submittals.

06 · The Bespoke

Built to Your Spec.

Our in-house engineering team designs and manufactures custom power protection solutions tailored to your exact requirements. From modified standard products to ground-up OEM designs, we build it in Los Angeles and ship direct.

With 48 years of manufacturing experience and ISO 9001 quality systems, your custom solution gets the same precision engineering as our standard product lines.

Discuss Your Project
480V 3Φ NEMA 3R 200kVA CUSTOMER SPEC 01 YOUR SPEC OLP ENGINEERING WAVEFORM ISO 9001 48 YEARS EXPERIENCE 02 WE ENGINEER OLP CUSTOM BUILT MADE IN LA 03 WE BUILD // CUSTOM OEM · BUILT TO YOUR SPEC · ISO 9001
07 · The Voices

What Engineers Say.

Online Power and their staff couple technical ability with speed, taking the complicated and turning it into the digestible. I have lost track of the number of times they have saved a job or offered the assurance a customer needed at the eleventh hour. Our reputation is strong because of our partnership with them.

Joe Gangl

JTH Lighting Alliance

Online Power has been our go-to for emergency lighting inverters. Their engineering team is responsive and the products are absolutely rock solid.

Alex Jenkins

Green MEP Engineering

I am always able to get quick, complete information from Online Power and with their broad range of lighting inverter product options and sizes I am always able to find something that fits the needs of my projects.

Nathan Short, PE

Energy Systems Design Inc.

08 · The Next Move

Ready to Spec Online Power?

Three ways to get moving — request a quote, size a specific system, or train with our engineers.

Direct Line

(800) 227-8899

Los Angeles, CA

Email

sales@onlinepower.com

Mon-Fri · 6am-5pm PT

AB Bot
Online Power Engineering Assistant
// AB Bot · Powered by AI · Available 24/7 · Real engineers at (800) 227-8899