UL Listed NEMA Made in USA

Power Distribution Units

When off-the-shelf PDUs don't fit your voltage, enclosure, or monitoring requirements, we build to your spec. Custom PDUs integrating voltage regulation, isolation, and branch-circuit monitoring — rack, floor, or wall — with the outlet configs, breakers, and protocols your application demands.

Responds within 2 business hours

Configurations

Rack · Floor · Wall · Custom

Monitoring

SNMP v3 · Modbus · BACnet

Accuracy

±1% power measurement

Manufacturing

Build to order · ISO 9001

Overview

Regulation, isolation, and distribution in one chassis

Standard PDUs just distribute power. Online Power integrates voltage regulation, isolation transformers, and power distribution into single units giving you fewer boxes, less complexity, and a single point of accountability for your entire power chain.

Custom outlet configurations for any application

NEMA 5-15, NEMA 5-20, NEMA L6-30, IEC C13, IEC C19, bus bars, MIL-spec connectors, and hospital grade receptacles configured exactly as your equipment requires. No adapter cables, no outlet conversion, and no compromises on connection integrity.

Branch circuit monitoring at plus or minus 1 percent accuracy

Track voltage, current, power factor, and kWh at the individual circuit level for capacity planning, phase balancing, tenant billing, and PUE reporting. Remote visibility via SNMP, Modbus, or web interface means your facility team sees real-time load data from anywhere.

What your spec sheet won't tell you

AI and HPC workloads are pushing data center rack densities to 30 to 60 kilowatts per cabinet, far beyond the 5 to 8 kilowatts that standard rack PDUs support. Floor-standing PDUs feeding multiple racks through sub panels are increasingly necessary but catalog PDU vendors do not offer the custom configurations these high density deployments require. For medical OEM applications, the PDU embedded in an imaging system must meet UL 60601-1 medical grade requirements including leakage current, isolation, and EMC specifications that no standard data center PDU carries. For colocation billing, monitoring grade accuracy of plus or minus 2 to 3 percent is not adequate for tenant billing. You need plus or minus 1 percent or better conforming to ISO/IEC 62053-21. Verify your PDU vendor's measurement accuracy specification because many quote accuracy at full load but degrade significantly at the 20 to 40 percent load points where most circuits actually operate.

Codes & Standards

UL 891

Switchboards

UL 60601-1

Medical Electrical Equipment (OEM PDUs)

NEMA PB-2

Deadfront Distribution Switchboards

TIA-942

Data Center Infrastructure Standard

NEC Article 645

Information Technology Equipment

ISO/IEC 62053-21

Power Measurement Accuracy

Where It Gets Specified

Data Centers
Broadcast & Events
Industrial
Construction
Hospitals
Government

Custom Configuration

Every power distribution unit is built to your specific requirements. Contact our engineering team for custom panel board configurations and load analysis.

"In these uncertain times dealing with COVID-19, the US Government needed to build warehouses to help fight this tragedy. Time was critical so we turned to Online Power to provide 16 emergency lighting inverters. Online Power was able to build and ship all 16 units in 10 days. Great job Online Power."

Ready Electric Company

Electrical Contractor, Eckart Supply

Request a Quote
AB Bot
Online Power Engineering Assistant
// AB Bot · Powered by AI · Available 24/7 · Real engineers at (800) 227-8899

// Before we start

Hi, I'm AB Bot. To give you the best help, please share your name and email so our engineering team can follow up.

Your info goes directly to our engineering team.

You have reached the AB Bot session limit. Please call us directly at (800) 227-8899 or email sales@onlinepower.com for continued assistance.